| A I R C O N D I T I O N E R S |
AIR HANDLING UNITS
- AIR HANDLING UNITS |
|
Features
- Wide Range of Coils Offering - 4, 5, 6, 7, 8 Rows, and 8, 10, 12, 14 FPI for Chilled Water Optimized Coil Circuiting. DX Coil and Hot Water Coil are also available
- ZINCALLUME pre-painted steel panels can provide a good resistance to corrosion/suitable for outdoor durability
- Polyurethane CFC Free. CFC-FREE PU = Insitu CFC-Free Pu. Injected Panels with thermal conductivity factor of 0.019 w/mk and density of 40 kg/m³
- Drain Outlet. Powder Painted Sloped Galvanized Steel Drain Pan conforming to ASHRAE 62-89 assures complete drainage
- Externally Removable Panel
- Rib-Seal provides air tight seal between panels
and extruded aluminium framework
- AHU Selection Program - Windows Based Selection with ARI methods
Specification
|
Size |
Code |
Nominal
Air Flow (2.5m/s) (I/S) |
Nominal
Capacity* (kW) |
Basic
Unit Dimension** (mm)
(L x W x H) |
|
Horizontal |
Vertical |
|
0508A |
5A |
425 |
7.9 |
1110 x 910 x 610 |
610 x 910 X 1220 |
|
0508B |
5B |
614 |
11.4 |
1110 x 910 x 610 |
610 x 910 X 1220 |
|
0511 |
5D |
850 |
15.8 |
1110 x 1210 x 610 |
610 x 1210 x 1220 |
|
0612 |
6E |
1227 |
22.9 |
1210 x 1310 x 710 |
710 x 1310 x 1420 |
|
0713 |
7F |
1746 |
32.5 |
1310 x 1410 x 810 |
810 x 1410 x 1620 |
|
0813 |
8F |
2030 |
37.8 |
1410 x 1410 x 910 |
910 x 1410 x 1820 |
|
0914 |
9G |
2620 |
48.8 |
1510 x 1510 x 1010 |
1010 x 1510 x 2020 |
|
0916 |
9I |
2879 |
53.6 |
1510 x 1710 x 1010 |
1010 x 1710 x 2020 |
|
1018 |
CK |
3587 |
66.8 |
1610 x 1910 x 1110 |
1110 x 1910 x 2220 |
|
1118 |
DK |
4201 |
78.2 |
1610 x 1910 x 1210 |
1110 x 1910 x 2420 |
|
1319 |
FL |
5192 |
96.7 |
1710 x 2010 x 1410 |
1210 x 2010 x 2620 |
|
1422 |
GN |
5900 |
109.8 |
1910 x 2310 x 1510 |
1410 x 2310 x 3120 |
|
1522 |
HN |
6372 |
118.6 |
2110 x 2310 x 1610 |
1610 x 2310 x 3320 |
|
1722 |
JN |
7316 |
136.2 |
2110 x 2310 x 1810 |
1610 x 2310 x 3520 |
|
1724 |
JO |
8260 |
153.8 |
2110 x 2510 x 1810 |
1610 x 2510 x 3520 |
|
1725 |
JP |
8968 |
166.9 |
2210 x 2610 x 1810 |
1710 x 2610 x 3620 |
|
1926 |
LQ |
9912 |
184.5 |
2210 x 2710 x 2010 |
1710 x 2710 x 3820 |
|
2127 |
MR |
11564 |
215.3 |
2410 x 2810 x 2210 |
1910 x 2810 x 4220 |
|
2230 |
NS |
13688 |
254.8 |
2720 x 3110 x 2310 |
2110 x 3110 x 4420 |
|
2234 |
NT |
16048 |
298.7 |
2720 x 3510 x 2310 |
2110 x 3510 x 4420 |
|
2434 |
OT |
17464 |
325.1 |
2720 x 3510 x 2510 |
2110 x 3510 x 4620 |
|
2636 |
QU |
20296 |
377.8 |
3020 x 3710 x 2710 |
2410 x 3710 x 5020 |
* Nominal capacity is estimated based on
44F EWT and 54F LWT and 80/67F EAT on A 4 rows Chilled
Water Coils.
** Basic unit dimension based on std. 2/2A, 25mm casing fan coil section with add-on HVF Filter Track.
|
|
|
| |
|
|
|